QIAseq and GeneRead Library Prep Kits
- Fast, one-tube procedure that allows up to 50% time savings
- High yields from minimal amounts of starting material
- Unbiased amplification with an optional, high-fidelity amplification step
- Multiplexing, high-throughput capability
GeneRead Library Prep Kits provide an optimized and efficient workflow for library preparation in next-generation sequencing (NGS) applications. The kits allow fast and efficient preparation of DNA libraries that are for use on NGS platforms from Illumina and the Ion Torrent instrument from Life Technologies.Procedures canbe automated on theQIAcube.
Need a quote for your research project or would you like to discuss your project with our specialist team? Contact Us
- Buy Products
- Product Details
Buy Products
Cat No./ID:180412 QIAseq 1-Step Amplicon Library Kit (12) $325.00 For 12 reactions: 1-Step Amplicon Enzyme Mix, 4x 1-Step Amplicon Buffer, Primer Mix Illumina Library Amp, HiFi PCR Master Mix, RNase-Free Water. Adapters sold separately. |
Cat No./ID:180415 QIAseq 1-Step Amplicon Library Kit (96) $2,997.00 For 96 reactions: 1-Step Amplicon Enzyme Mix, 4x 1-Step Amplicon Buffer, Adapter Plate 96-plex Illumina, Primer Mix Illumina Library Amp, HiFi PCR Master Mix, RNase-Free Water |
Cat No./ID:180432 GeneRead DNA Library I Core Kit (12) $318.00 For 12 reactions: Buffers and reagents for end-repair, A-Addition, and ligation, for use with Illumina instruments |
Cat No./ID:180434 GeneRead DNA Library I Core Kit (48) $1,083.00 For48 reactions: Buffers and reagents for end-repair, A-Addition, and ligation, for use with Illumina instruments |
Cat No./ID:180435 GeneRead DNA Library I Kit (96) $2,908.00 Buffers and reagents for end-repair, A-addition, ligation and library amplification; for use with Illumina instruments; includes a plate containing 96 adapters with different barcodes (pierceable foil seal allowing usage of defined parts of plate) |
Cat No./ID:180455 GeneRead DNA I Amp Kit (100) $364.00 For 100 reactions: Ready-to-use library amplification master mix and primer mix, for use with Illumina instruments |
Cat No./ID:180462 GeneRead DNA Library L Core Kit (12) $309.00 For 12 reactions: Buffers and reagents for end-repair, ligation and nick-repair, for use with Ion Torrentinstruments |
Cat No./ID:180473 QIAseq FX DNA Library Kit (24) $864.00 Buffers and reagents for DNA fragmentation (including end repair and A-addition), ligation and library amplification; for use with Illumina instruments; includes a plate containing 24 combinatorial dual index adapters with different bar codes (pierceable foil seal, allowing usage of defined parts of plate) |
Cat No./ID:180475 QIAseq FX DNA Library Kit (96) $3,423.00 Buffers and reagents for DNA fragmentation (including end repair and A-addition), ligation and library amplification; for use with Illumina instruments; includes a plate containing 96 combinatorial dual index adapters with different bar codes (pierceable foil seal, allowing usage of defined parts of plate) |
Cat No./ID:180485 GeneRead DNA L Amp Kit (100) $353.00 For 100 reactions: Ready-to-use library amplification master mix and primer mix, for use with Ion Torrentinstruments |
Cat No./ID:180492 QIAseq Ultralow Input Library Kit (12) $331.00 For 12 reactions: buffers and reagents for Ultralow Input End Polishing, Ultralow Input Ligation and HiFi library amplification. 12-plex adapters sold separately. For use with Illumina instruments. |
Cat No./ID:180495 QIAseq Ultralow Input Library Kit (96) $3,050.00 For 96 reactions: buffers and reagents for Ultralow Input End Polishing, Ultralow Input Ligation and HiFi library amplification. Includes 96-plex Adapter Plate with individually pierceable foil sealed wells. For use with Illumina instruments. |
Cat No./ID:180985 GeneRead Adapter I Set A 12-plex (144) $1,283.00 For 144 reactions: 12 barcoded adapters for ligation to DNA library, for use with Illumina instruments |
Cat No./ID:180986 GeneRead Adapter I Set B 12-plex (144) $1,250.00 For 144 reactions: 12 barcoded adapters for ligation to DNA library, for use with Illumina instruments |
Cat No./ID:180994 GeneRead Adapter L Set 12-plex (72) $846.00 For 72 reactions: 12 barcoded adapters for ligation to DNA library, for use withIon Torrentinstruments |
Product Details
High yields of library DNA with uniform coverage distribution
GeneRead Library Prep Kits provide an efficient and optimized workflow to reproducibly generate high yields of DNA library, with minimal sequence bias and low error rates, for use on NGS platforms from Illumina or the Ion Torrent instrument from Life Technologies. Highly efficient ligation reactions and an optional, high-fidelity amplification step ensure superior library yields with uniform coverage distribution, even from as low as 50 ng starting material (see figures High yields of library DNA with uniform coverage distribution and Superior yields of library DNA).Low error rates with minimal sequence bias
To ensure maximum yields from minimum amounts of starting material, GeneRead Library Prep Kits include an innovative high-fidelity master mix that includes GeneRead HiFi Polymerasefor an optional amplification step. GeneRead HiFi Polymeraseisa unique, highly specific and processive enzyme thatdelivers accurate amplification of library DNA with low error rates and minimum bias (see figure Low error rates with minimal sequence bias due to high-fidelity amplification).Lower sequence bias when amplifying GC- and AT-rich regions
In standard PCR amplification procedures, regions of DNA with high AT or GC content can result in little or no amplification, leading to misleading sequence data and NGS results. The GeneRead HiFi Polymerase, together with its unique buffer formulation, ensures uniform amplification of genomic regions that contain highly variable GC content, thereby ensuring even coverage in subsequent sequencing reactions (see figure Better sequence coverage).Procedure for generating Illumina-compatible DNA libraries
Samples consisting of longer DNA fragments are firstsheared into a random library of fragments that are a median fragment size of 300 bp (when using theIllumina MiSeq instrument, version 1), or 500 bp (when using the Illumina MiSeq instrument, version 2), in length. Following fragmentation, the ends of the DNA fragments are repaired and an A-overhang is added at the 3"-end of each strand. Afterwards, adaptors, which are necessary for amplification and sequencing, are ligated to both ends of the DNA fragments. Barcode adapters, which contain a unique identifying sequence, are also available with the GeneRead Library Prep (I) Kit and enable multiplex sequencing reactions to be performed. Fragments are then size selected and purified. Cleanup and size selection can be done using the GeneRead Size Selection Kit (cat. no. 180514), which allows precise, column-based size selection of DNA (see figure Precise size selection). To ensure maximum yields from minimum amounts of starting material, an optional high-fidelity amplification step can also be performed.Procedure for generating Ion Torrent-compatible DNA libraries
Samples consisting of longer DNA fragments are firstsheared into a random library of fragments that are a median fragment size of 400 bp (when using the Ion Torrent PGM instrument), or 200 bp (when using the Ion Proton instrument), in length. Following fragmentation, the ends of the DNA fragments are repaired. Afterwards, adaptors, which are necessary for amplification and sequencing, are ligated to both ends of the DNA fragments. Barcode adapters, which contain a unique identifying sequence, are also available with the GeneRead Library Prep (L) Kit and enable multiplex sequencing reactions to be performed. Fragments are then size selected and purified. To ensure maximum yields from minimum amounts of starting material, an optional high-fidelity amplification step can be performed.Product Resources
Customers who bought these products also bought
- Cat No./ID:181940
GeneRead DNAseq Panel PCR Kit V2 (12)
GeneRead HotStarTaq polymerase, GeneRead DNAseq Panel 5x PCR Buffer, Nuclease-free Water; enough for 12 samples (4-pool panels) or 24 samples (1-pool panels)$225.00Add To Cart - Cat No./ID:333895
QIAseq SARS-CoV-2 Primer Panel (24)
Reagents and primers for reverse transcription, whole genome amplification and downstream Illumina sequencing; for 24 reactions
$260.00Add To Cart - Cat No./ID:333896
QIAseq SARS-CoV-2 Primer Panel (96)
Reagents and primers for reverse transcription, whole genome amplification and downstream Illumina sequencing; for 96 reactions
$960.00Add To Cart - Cat No./ID:180015
QIAseq cfDNA Library Kit (96)
For 96 reactions on Illumina® sequencers: enzymes and buffers for cfDNA library prep, Illumina Adapter Plate 96-plex, Illumina Library Amplification Primer and PCR Master Mix$3,050.00Add To Cart - Cat No./ID:180514
GeneRead Size Selection Kit (50)
For 50 reactions: Spin columns and buffers$142.00Add To Cart - Cat No./ID:181942
GeneRead DNAseq Panel PCR Kit V2 (96)
GeneRead HotStarTaq polymerase, GeneRead DNAseq Panel 5x PCR Buffer, Nuclease-free Water; enough for 96 samples (4-pool panels) or 192 samples (1-pool panels)$886.00Add To Cart - Cat No./ID:180312
QIAseq UDI Y-Adapter Kit A (96)
Box containing dual bar-coded Unique Dual Sample Index Y-adapters; plate-format for 96 samples; no library preparation reagents included
$1,440.00Add To Cart - Cat No./ID:180310
QIAseq UDI Y-Adapter Kit (24)
Box containing dual bar-coded Unique Dual Sample Index Y-adapters; plate-format for 24 samples
$375.00Add To Cart - Cat No./ID:206742
UCP Multiplex PCR Kit (100)
For 100 x 20 µl PCR reactions: 1 x 500 µl UCP Multiplex PCR Master Mix (4x), 1 x 200 µl UCP Template Tracer (25x), 1 x 50 µl UCP Master Mix Tracer (125x), 1 x 1.9 ml UCP Water$180.00Add To Cart - Cat No./ID:180773
QIAseq Stranded mRNA Select Kit (24)
For mRNA enrichment and strand-specific RNA-seq library preparation of 24 samples: Kits include magnetized reaction cleanup beads and sample index adapters for Illumina NGS platforms
$1,247.00Add To Cart - Cat No./ID:180477
QIAseq FX DNA Library UDI Kit (24)
Buffers and reagents for DNA fragmentation (including end repair and A-addition), ligation and library amplification; for use with Illumina instruments; includes a plate containing 24 Unique Dual Index Y-adapters.
$907.00Add To Cart - Cat No./ID:180745
QIAseq Stranded Total RNA Lib Kit (96)
For strand-specific RNA-seq library preparation of 96 samples: Kits include magnetized reaction cleanup beads and sample index adapters for Illumina NGS platforms$3,967.00Add To Cart - Cat No./ID:339372
miRCURY LNA Probe PCR Kit (800)
For 800 reactions: 2X QuantiNova Probe Master Mix, 10X miRCURY Probe Univ. Primer, Rox Reference Dye, RNase-Free Water
$559.00Add To Cart - Cat No./ID:207045
QuantiTect Whole Transcriptome Kit (100)
For 100 x 50 µl reactions: 100 µl T-Script Enzyme, 400 µl T-Script Buffer, 100 µl Ligation Enzyme 1, 100 µl Ligation Enzyme 2, 200 µl Ligation Reagent, 600 µl Ligation Buffer, 100 µl REPLI-g Midi DNA Polymerase, 2 x 1.45 ml REPLI-g Midi Reaction Buffer$3,269.00Add To Cart - Cat No./ID:180830
GeneRead qPCR SYBR Green/Fluor Mastermix (2)
Two (2) tubes each containing 1.35 ml of 2x solution, sufficient for 100 standard 25 µl reactions$239.00Add To Cart - Cat No./ID:206143
QIAGEN Multiplex PCR Kit (100)
For 100 x 50 µl multiplex PCR reactions: 2x QIAGEN Multiplex PCR Master Mix (providing a final concentration of 3 mM MgCl2, 3 x 0.85 ml), 5x Q-Solution (1 x 2.0 ml), RNase-Free Water (2 x 1.7 ml)$301.00Add To Cart - Cat No./ID:333314
QIAseq Library Quant Assay Kit
1 tube of Primer Mix (500 µl), 1 bottle of Dilution Buffer (30 ml), 1 tube DNA Standard (100 µl), and 5 tubes GeneRead qPCR SYBR Green (1.35 ml) for sample library quantification prior to NGSSelect Targets - Cat No./ID:301005
Attractene Transfection Reagent (1 ml)
Attractene Transfection Reagent for up to 660 transfections in 24-well plates$422.00Add To Cart - Cat No./ID:158388
Gentra Puregene Cell Kit (6.7 x 109)
For (6.7 x 109) cells: Reagents$1,034.00Add To Cart - Cat No./ID:51104
QIAamp DNA Blood Mini Kit (50)
For 50 DNA minipreps: 50 QIAamp Mini Spin Columns, QIAGEN Protease, Reagents, Buffers, Collection Tubes (2ml)$167.00Add To Cart