QIAgility

Request Demo
Product picture
For rapid, high-precision automated PCR setup
  • Automated PCR setup in all formats
  • Convenient, easy-to-use software
  • Pre-optimized experiment setup
  • Standardized results and increased productivity
  • Elimination of manual pipetting steps
The QIAgility is a compact benchtop instrument that enables rapid, high-precision setup of PCR experiments with ready-to-use software for ease and convenience. The software provides step-by-step guidance for worktable setup and automatic calculation of all mixes, eliminating the need to program pipetting steps. Just select the kit and cycler, define your targets and start the run. For added flexibility the QIAgility is operated via a laptop computer.Explore the virtual demoto learn more about the QIAgility.​QIAgility operates in conjunction with QIAgility Accessoriesand QIAgility Consumables.
  • Buy Products
  • Product Details
  • Service Plans
  • Specifications
  • Product Resources

Buy Products

Cat No./ID:9001532
QIAgility System HEPA/UV (incl. PC)
Inquire

Instrument and service agreement package: robotic workstation for automated PCR setup (with UV light and HEPA filter), notebook computer and QIAgility software; includes installation, application training and one-year warranty on labor, travel and parts.

Cat No./ID:9001903
QIAgility, HEPA/UV, PC, Priority
Inquire

Instrument and service agreement package: robotic workstation for automated PCR setup (with UV light and HEPA filter), notebook computer and QIAgility software; includes installation, application training, Full Agreement for two years with a two business day response time and two preventive maintenance visits.

Cat No./ID:9001904
QIAgility, HEPA/UV, PC, PrioPLUS
Inquire

Instrument and service agreement package: robotic workstation for automated PCR setup (with UV light and HEPA filter), notebook computer and QIAgility software; includes installation, application training, Full Agreement for three years with a two business day response time and three preventive maintenance visits.

Cat No./ID:9001908
QIAgility HEPA/UV (w/o PC) System
Inquire

Instrument and service agreement package: robotic workstation for automated PCR setup (with UV light and HEPA filter) and QIAgility software; includes installation, application training and one-year warranty on labor, travel and parts. Does not include a laptop.

Cat No./ID:9001909
QIAgility HEPA/UV (w/o PC), Priority
Inquire

Instrument and service agreement package: robotic workstation for automated PCR setup (with UV light and HEPA filter) and QIAgility software; includes installation, application training, Full Agreement for two years with a two business day response time and two preventive maintenance visits. Does not include a laptop.

Cat No./ID:9001910
QIAgility HEPA/UV (w/o PC), PrioPLUS
Inquire

Instrument and service agreement package: robotic workstation for automated PCR setup (with UV light and HEPA filter) and QIAgility software; includes installation, application training, Full Agreement for three years with a two business day response time and three preventive maintenance visits. Does not include a laptop.

The QIAgility is intended for molecular biology applications. This product is not intended for the diagnosis, prevention, or treatment of a disease.

The QIAgility, if used in combination with QIAGEN kits indicated for use with the QIAgility instrument, is intended for the applications described in the respective QIAGEN kit handbooks. If the QIAgility instrument is used with kits other than QIAGEN kits, it is the user’s responsibility to validate the performance of such product combination for any particular application.

Product Details

9
Unrivaled pipetting precision and reproducibility of the QIAgility for master mix solutions
A reaction mix was prepared manually using 5 parts of 2x Rotor-Gene SYBR Green PCR Master Mix and 3 parts of RNase free water (ready-made reaction mix). An experiment was then defined in the QIAgility Setup Manager for the Rotor-Gene SYBR Green PCR Kit with a total reaction volume of 25 µl and a sample input volume of 5 µl, resulting in the transfer of 20 µl of the ready-made reaction mix. The transfers were made into pre-weighed 200 µl single tubes (n=36 per instrument). The tubes were weighed again after the transfer and the weight difference was considered to calculate the transferred volume. For each instrument, the pipetting precision was determined as CV (%). The data shows the mean of the CV values (bars; in %) ± S.D. (error bars) of each individual instrument. The pipetting precision or CV, respectively, was nearly 3 % for all instruments tested. The indicated CV values (%) demonstrate that the QIAgility instrument has high performance rate in terms of precision and repeatability when pipetting ready-made reaction mix as shown on all 4 instruments.
9
High system linearity of QIAgility
Human gDNA with a stock concentration of 1.5 µg/µl was diluted with the QIAgility six times in the ratio of 1:2 per dilution step using RNase free water as diluent. The dilution series was prepared in replicates of 3. The nucleic acid concentration of the dilutions was determined using the QIAxpert UV/VIS spectrophotometer (DNA QIAamp Application). The mean measured quantifications were plotted against the mean theoretical nucleic acid concentrations assuming a perfect 1:2 dilution. The resulting plot demonstrates the exceptional linearity of QIAgility dilution with a high regression coefficient of >0.999. Quantifications of serial dilutions of gDNA prepared using the QIAgility are in high concordance with actual concentrations.
9
Comparison of manual and automated assay setup using series dilutions
A QuantiNova SYBR Green assay setup was performed using the QIAgility operated with its Setup Manager Software and this was compared to a manual setup done in parallel. A manually prepared 1:10 dilution series from a stock of human gDNA with a concentration of 60 ng/µl was used in a ß-actin assay. Each dilution was tested in quadruplicates (n=4). The manual and QIAgility-prepared assay points were amplified in the same Rotor-Gene Q run. The data is represented as a box plot of the CT value calculated using the Q-Rex Software for each template concentration and setup employed. A highly similar PCR performance is observed between manual and automated assay setup over a series of sample concentrations.
9
Exceptional pipetting precision and accuracy spanning over a broad volume range
The Artel MVS system was employed to determine the pipetting precision of the QIAgility instrument operated by the QIAgility Setup Manager Software. The QIAgility dispensed the Artel solutions (selected according to the Artel MVS User Manual) into the Artel buffer. Three runs were performed on three QIAgility instruments that were used to pipet an entire volume range (1, 2, 5, 10, 20, 50, 100, and 200 µl), in replicates of 12. For each run and volume (n=12) the coefficient of variation (CV) was calculated to determine the pipetting precision of the QIAgility. The data shows the mean of the CV values (bars; in %) ± standard deviation (S.D.) of the CV values as error bars. The red lines depict the claimed specifications. The indicated CV values (%) demonstrate that the QIAgility instrument performs within its claimed specifications and even better.
Performance
The QIAgility fully automates proven QIAGEN PCR kits for use with various workflows, and offers pure pipetting precision, enhanced safety features, and exceptional reliability and reproducibility.Unmatched pipetting precision with QIAgilityThe QIAgility instrument operated by the QIAgility Setup Manager Software demonstrates exceedingly high accuracy and precision of dispensed volumes as verified by the Artel MVS system (see figure “Exceptional pipetting precision and accuracy spanning over a broad volume range”). These results indicate that the QIAgility can produce automated, high-performance liquid dispensing results, while avoiding common errors that can be associated with manual pipetting and thereby reducing the time to result. Regardless of whether you pipetwater orQIAGEN ready-made reaction mix to set up a PCR experiment, the QIAgility instrument can dispense volumes that are highly precise and also generate significantly reproducible replicates (see figure “Unrivaled pipetting precision and reproducibility of the QIAgility for master mix solutions”).High performance PCR setup using QIAgilityA QuantiNova SYBR Green PCR assay setup was performed manually and automated in parallel using the QIAgility along with its Setup Manager Software. The amplification run was done on the Rotor-Gene Q and resulting data analyzed using the Q-Rex Software. Consistent results were obtained from both manual and automated reaction setup using the same template dilutions (see figure “Comparison of manual and automated assay setup using series dilutions”).Exceptional linearity of QIAgilityQIAgility exhibits excellent linearity and assures accurate and reliable use of sample for an assay. To assess the linearity of the system, pure gDNA was serially diluted using the QIAgility and measured for their concentrations on the QIAxpert. The quantifications from the QIAxpert were plotted against the known concentration values, and the resulting plot demonstrates the exceptional linearity (with a regression coefficient of >0.999) of QIAgility (see figure “High system linearity of QIAgility”).
Principle
Automated PCR setup is rapid and reliable and eliminates manual pipetting steps that are typically prone to human error.Liquid-handling tasks are performed by the single-channel pipetting head, which provides fast transfer of liquids with various types of plasticware.For example, 96 samples with the QuantiFast SYBR Green PCR Kit with 2 standard series can be setup in approximately45 minutes.The worktable features a flexible layout and supports almost all kinds of cyclers and labware, giving high application versatility. Dynamic liquid-level sensing, facilitated by conductive filter tips offers maximum safety control.The advanced design of the QIAgility delivers improved process safety, giving you peace of mind. A built-in sensor ensures that the instrument pauses when the hood is opened during a run, protecting users from moving parts. The UV light ensures effective worktable decontamination and the HEPA filter provides positive clean air pressure throughout PCR setup.QIAgility is a compact benchtop instrument with a very small footprint. It fits easily onto most lab benches and can be readily moved into biosafety level laboratories. For added flexibility, the QIAgility comes with a laptop computer. To reduce your work load, comprehensive run reports containing all run information are generated automatically during each protocol.
Procedure
Quick and easy setup of your PCR experiment with the new Setup Manager Software​Let the QIAgility do the pipetting and save your valuable time
Applications
The instrument is highly suited for laboratories performing PCR and RT-PCR reactions with applications in:​
  • Gene expression analysis
  • Genotyping
  • Cloning
  • Pathogen detection
  • Food and veterinary testing
Please click here to get more information on which kits are currently supported by the new Setup Manager Software for gene expression analysis and pathogen detection.Check the instrument operating software and protocol files under product resources for more information.
Services

Is your plate or tube not supported in the QIAgility software? Contact QIAGEN Technical Services to request a new plate or tube to suit your workflow.

Have your throughput demands increased? Do you want to expand your application range or further streamline workflows? Do you need to manage more complex samples? Do you need improved connectivity?

If the answer to any of these questions is yes, then QIAGEN’s trade-in/trade-up program is just right for you!

QIAGEN makes it easy to keep up to speed with the latest automation and sample processing technologies. Simply exchange an old instrument for a new one. Improve your efficiency by trading in a competitor instrument or trading up with an older QIAGEN instrument.

Learn more about trade-in/trade-up opportunities.

Service Plans

Cat No./ID:9241764
QIAgility, Premium Agreement
Inquire

On-site QIAgility instrument repair, including travel, labor and parts, for a period of one year. Response time of next business day. Includes one Preventive Maintenance or Inspection Service during the Premium Agreement period.

Cat No./ID:9241763
QIAgility, Full Agreement
Inquire

On-site QIAgility instrument repair, including travel, labor and parts, for a period of one year. Response time of two business days. Includes one Preventive Maintenance or Inspection Service during the Full Agreement period.

Cat No./ID:9245243
QIAgility, Core Agreement
Inquire

For the QIAgility, one on-site repair service and one on-site Preventive Maintenance or Inspection Service, including travel, labor and spare parts for a period of one year. Response time of five business days. Includes a 10% discount on additional repair service during the Core Agreement period.

Cat No./ID:9241776A
QIAgility, Preventive Subscription
Inquire

One on-site Preventive Maintenance or Inspection Service visit for the QIAgility, including travel, labor and parts. Includes a 10% discount on repair services during the Preventive Subscription period.

Cat No./ID:9002887
QIAgility HEPA/UV Platform System PRV-1
Inquire

Instrument and service agreement package: robotic workstation for automated PCR setup (with UV light and HEPA filter), notebook computer and QIAgility software; includes installation, application training and one preventive maintenance visit. One-year warranty on labor, travel and parts are also included.

Cat No./ID:9002888
QIAgility HEPA/UV System PRV-1
Inquire

Instrument and service agreement package: robotic workstation for automated PCR setup (with UV light and HEPA filter) and QIAgility software; includes installation, application training and one preventive maintenance visit. One-year warranty on labor, travel and parts also included. Does not include a laptop.

The QIAgility is intended for molecular biology applications. This product is not intended for the diagnosis, prevention, or treatment of a disease.

The QIAgility, if used in combination with QIAGEN kits indicated for use with the QIAgility instrument, is intended for the applications described in the respective QIAGEN kit handbooks. If the QIAgility instrument is used with kits other than QIAGEN kits, it is the user’s responsibility to validate the performance of such product combination for any particular application.

Specifications

Features
Specifications
Accessories (supplied)2 x Adapter, 96 x 0.2 ml PCR Tubes 1 x Adapter, Flip-Cap 32 x 1.5 ml Tapered Base 1 x Adapter, 72 x 0.1 ml Strip Tubes 1 x Master Mix Block, 5 x 5 ml 1 x Master Mix Block, 1 x 5 ml, 4 x 2 ml 1 x Master Mix Block, 1 x 5 ml, 4 x 1.5 ml 1 x Reagent Block, 16 x 0.2 ml / 2 ml Flat / 1.5 ml Tapered Tubes 4 x Tip Rack Holder for 96-Tip Rack The adapters are intended to hold tubes or plates.
CommunicationsUSB and RS232
Conductive Filtered Tips50 µl and 200 µl Conductive Filtered Tips for liquid-level sensing
Consumables (supplied)10 racks of 50 µl Conductive Filtered Tips (960); 10 racks of 200 µl Conductive Filtered Tips (960); 25 x 5 ml tubes; 100 x 0.2 µl PCR tubes; 3 Tip Disposal Boxes
DimensionsHeight: 45 cm (18 in.), instrument lid closed; Height: 86 cm (34 in.), instrument lid open; Width: 54 cm (21 in.); Depth: 63 cm (25 in.), without cables
Electrical100–240 V AC, 250 VA, 50–60 Hz
HEPA filterPreinstalled dual-cartridge HEPA filter system provides positive pressure clean air within the closed hood.
HumidityOperating humidity: 40–70%
Liquid-level sensingMinimum detection volume (10 µl in 200 µl PCR tubes). Only functional in combination with QIAGEN Conductive Filtered Tips.
Notebook (supplied)QIAgility comes with a notebook computer for added flexibility.
Pipetting headSingle channel
Place of operationFor indoor use only
Pollution level2
PrecisionCV <1%, 5–200="" µl="" (dry-well="" transfer)="" cv=""><5%, 2–5="" µl="" (wet-well="" transfer)="" cv=""><10%, 1="">
SoftwareSupplied with unlimited user license. Free upgrades by Web download.
Table capacity6 x SBS positions (127.76 x 85.48 mm) for adapters and Tip Rack Holders 1 x Master Mix Block 1 x Reagent Block
TemperatureOperating temperature, 15–30 °C (59–86°F)
Tip disposalAll used tips ejected externally — no waste accumulation on the worktable
Tip volume1–200 µl
UV lampPreinstalled UV lamp for worktable decontamination
Warranty1-3 years warranty, depending on service package
Weight41 kg (90.2 lb)

Product Resources

You are not authorized to download the resource

Brochures & Guides (6)
  • Sort options
    • Sort alphabetically
QIAgility — Pure Precision - (EN)
Rapid, high-precision PCR setup
Show details
(EN) - Maximizing PCR and RT-PCR success — Third Edition
Addressing critical factors and new solutions
Show details
QIAgility
Show details
Advanced Workflow Solutions from Crime Scene to Court
Show details
Forensic Casework Automation Workflows – Digital Product Profile
Explore our new, easy-to-navigate digital Product Profile!
Show details
When optimal instrument performance is critical, choose QIAGEN Premium Service Agreement
Show details
FAQs (5)
  • Sort options
    • Sort alphabetically
Are Rotor-Gene Kits compatible with reaction setup using the QIAgility instrument?
FAQ ID -2116
View
Can Vapor-Lock be used with samples processed on the QIAgility?
FAQ ID -2153
View
What are the advantages and disadvantages of turning on the tip “re-use” feature on the QIAgility?
FAQ ID -3064
View
How long does it take to set up a 96-well plate PCR reaction on the QIAgility?
FAQ ID -3066
View
Can I use a bar code scanner or reader on the QIAgility?
FAQ ID -3067
View
Technical Information (3)
  • Sort options
    • Sort alphabetically
(EN) - Maximizing end-point PCR success with QIAGEN"s automatable PCR solutions
Show details
QIAgility System and 21 CFR Part 11 Regulations
Show details
File-based Interfaces of the QIAgility Setup Manager Software
Show details
Scientific Posters (1)
  • Sort options
    • Sort alphabetically
(EN) - Streamlined forensic workflow with the Investigator Quantiplex Kit and automated reaction setup
Show details
Instrument User Manuals (4)
  • Sort options
    • Sort alphabetically
QIAgility Important Note
Important note regarding new QIAgility declaration of conformity and instrument symbols
Show details
QIAgility Unpacking and Installation Instructions
Show details
QIAgility User Manual
For use with QIAgility and QIAgility Setup Manager Software
Show details
QIAgility User Manual
For use with QIAgility Operating Software version 4.17.1
Show details
Protocol Files (1)
  • Sort options
    • Sort alphabetically
QIAgility Q Protocols and Descriptions (for use with QIAgility Operating Software 4.17.1)
These protocol files can only be used with QIAgility Operating software version 4.17 software and are not compatible with the new QIAgility Setup Manager software.QIAgility Setup Manager software offers a complete solution for qPCR setup optimized for use with QIAGEN gene expression kits, such as QuantiTect, QuantiFast, QuantiNova and Rotor-Gene Kits.The application spectrum of the QIAgility Setup Manager software will be expanded in the future with development of plug-ins for genotyping, pathogen testing, veterinary testing and food testing.
Show details
Operating Software (2)
  • Sort options
    • Sort alphabetically
QIAgility Setup Manager Software, version 1.3.1 (Windows platforms)
Instrument operating software including the QIAgility Setup Manager Gene Expression, Pathogen Detection, Sample Pooling and Generic PCR plug-in.The software offers a complete solution for qPCR setup, sample normalization, CE loading, certain liquid handling, as well as sample pooling. The Gene Expression and Pathogen Detection plug-ins are optimized for use with QIAGEN gene expression and pathogen detection kits, such as QuantiTect, QuantiFast, QuantiNova and Rotor-Gene kits. The Generic PCR plug-in allows flexible qPCR setup, liquid handling and support for the whole HID workflow.For software installation instructions, please refer to the QIAgility Unpacking and Installation Instructions or to the QIAgility User Manual, chapter 4.4.Important: It is not possible to install both QIAgility Setup Manager Software and QIAgility Operating Software 4.17.1 on the same computer. Please uninstall QIAgility Operating Software 4.17.1 before installing QIAgility Setup Manager Software. For more information, contact QIAGEN Technical Services. Note: QIAgility Operating Software is not compatible with CAS-1200 instruments. Download the latest CAS-1200 operating software.
Show details
QIAgility Operating Software, version 4.17.1 (Windows platforms)
Instrument operating software designed for flexible use in various applications. Use this software for all applications other than gene expression and pathogen detection.For gene expression and pathogen detectionapplications, we recommend using the QIAgility Setup Manager Software. Important: It is not possible to install both QIAgility Operating Software 4.17.1 and QIAgility Setup Manager Software on the same computer. Please uninstall QIAgility Setup Manager Software before installing QIAgility Operating Software 4.17.1. For more information, contact QIAGEN Technical Services. Note: QIAgility Operating Software is not compatible with CAS-1200 instruments. Download the latest CAS-1200 operating software.
Show details
Validation Reports (1)
  • Sort options
    • Sort alphabetically
Validation Certificate QIAgility System HEPA/UV (incl. PC)
Show details
(1)
  • Sort options
    • Sort alphabetically
QIAgility & Rotor-Gene Q 全自动加样实时荧光定量 PCR 分析系统
Show details
Safety Data Sheets (7)
  • Sort options
    • Sort alphabetically
MSDS QIAgility HEPA/UV (w/o PC) System
MSDS QIAgility HEPA/UV Platform System PRV-1
MSDS QIAgility HEPA/UV System PRV-1
MSDS QIAgility HEPA/UV (w/o PC) System
MSDS QIAgility, Premium Agreement
MSDS QIAgility, Preventive Subscription
MSDS QIAgility, Core Agreement
fragment fix placeholder

Customers who bought these products also bought

  • Cat No./ID:9018952
    /us/products//instruments-and-automation/accessories/qiagility-accessories/

    Reagent Block, 16x0.2ml/1.5ml Tapered-Base Tubes

    Reagent Block; intended to hold reagents and standards on the instrument worktable; holds 16 x 0.2 ml PCR tubes and 16 x 1.5 ml Tapered-Base Tubes
    $413.00
    Add To Cart
品牌介绍

QIAGEN是一家专业化致力于生物分子样品制备解决方案的跨国经营企业,总部位于德国。1984年,QIAGEN在德国成立,1996年在美国纽约纳斯达克上市。

QIAGEN拥有超过1000项专利和认可证明,在18个国家设立了分公司,代理商服务国超过40个,在全球有超过400000的用户。QIAGEN提供的产品超过500类,包括各种试剂,耗材和自动化纯化工作站。这些产品用于样品采集,稳定,核酸或蛋白的分离,纯化和检测中,不仅广泛的应用于科研领域的各个方面,在生物技术,制药,法医研究,食品安全检测,畜牧业和分子诊断领域也得到了广泛的应用。QIAGEN产品的卓越品质和在应用中的出色表现使得其成为样品处理中标准的代名词。


自营商城图标
厂家直采
全球直采 正品优价
正品保障图标
正品保障
厂家直发 有线跟踪
解放采购图标
正规清关
CIF100%正规报关,提供发票
及时交付图标
及时交付
限时必达 不达必赔